Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
A 6-Year Unloaded Hydroxyapatite-Coated Dental Implant Placed into an Extraction Socket in Conjunction with Nonresorbable Hydroxyapatite Grafting Material: Histologic Evaluation
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 22 , Issue 6
November/December 2002

Pages 575–581


A 6-Year Unloaded Hydroxyapatite-Coated Dental Implant Placed into an Extraction Socket in Conjunction with Nonresorbable Hydroxyapatite Grafting Material: Histologic Evaluation

Girolamo Stellino, MD, DDS, Luca Landi, DDS


PMID: 12516829
DOI: 10.11607/prd.00.0500

A submerged hydroxyapatite (HA)-coated implant placed into a fresh extraction socket in conjunction with a nonresorbable HA graft was harvested after 6 years of unloaded healing. The implant and surrounding bone were processed for histologic analysis. The HA coating appeared to be stable and homogenous. An excellent bone-to-implant contact could be found along the entire implant length. No signs of HA resorption or detachment were found. The HA graft was still recognizable histologically around the apical third of the implant. Light microscopy revealed a good osteoconductive ability of the HA particles, which did not show any signs of remodeling or resorption. These findings suggest that HA-coated implants may be able to maintain optimal osseointegration over time, even in the absence of loading. (Int J Periodontics Restorative Dent 2002;22:575–581.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help